When using the Power Station, always operate within the specified environmental temperature range. If the device is used outside the recommended range, the display may show a high or low temperature warning symbol (overtemperature indicator), and input/output functions will automatically stop.
Applicable Models: LiFePO₄ (Plus series / New series / 1500Ultra / 300D)
Discharge operating temperature: -10°C to 45°C
Charging operating temperature: 0°C to 45°C
Recommended Storage Temperature:
Short-term storage (within 1 month): -20°C to 45°C
It is recommended to perform a charge/discharge cycle once a month, even during short-term storage.
Medium-term storage (within 3 months): 0°C to 45°C
Perform a charge/discharge cycle every 3 months to maintain battery health.
Steps to Take When a High/Low Temperature or Overheat Warning Appears:
1. Immediately stop all input and output operations.
2. Move the device to an environment within the recommended temperature range.
3. Let the device rest for approximately 1–2 hours, then check whether the warning symbol disappears automatically.